{"product_id":"cl8r-super-large-capacity-low-speed-super-large-capacity-low-speed","title":"CL8R Super-Large Capacity Low Speed Super-Large Capacity Low Speed","description":"\u003cp\u003eCL8R super-large capacity refrigerated centrifuge , a new and smart centrifuge, which is jointly developed by the well-known centrifuge manufacturer and national key university, It has passed the MCA test and rotor service life test by authority agency in the United States. Max capacity up to 8x2200ml, it is the preferred product in the fields of blood bank, pharmacy and biological products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCarbon Fiber Rotor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe carbon fiber rotor, passed 100,000 times life service test in 2017, features light weight, chemical corrosion resistance, high mechanical strength, long service life , large capacity as well as high speed (Max speed 9000rpm with 6x1000ml angle rotor ), providing high efficient and perfect product for bio-pharmacy, biological products, chemical industry etc.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0812\/6427\/9777\/files\/Product_advantages.png?v=1772787584\" style=\"width: auto;\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic door locking system (optional)\u003c\/strong\u003e\u003cbr\u003eThe centrifuge door can be opened or closed by a single soft touch of a button. Door lid come with intelligent anti pinch device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic suction device of centrifuging windshield (optional)\u003c\/strong\u003e\u003cbr\u003eThe windshield is sucked to the door lid when opened without labor intervention prevent it from falling down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Structure\u003c\/strong\u003e\u003cbr\u003eThe overall unit has passed MCA (Maximum Credible Accident test ),After MCA is generated, the centrifuge door lid shall not be opened, and no solid greater than 0.5mm shall blown out of the centrifuge chamber, the position movement shall not exceed 30cm, ensure the personal safety of instrument operator to the greatest extent. ( MCA test video can be provided)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Material\u003c\/strong\u003e\u003cbr\u003eCentrifuge chamber adopt 2mm thick 316L stainless steel , Housing (3mm Q235 steel ), Containment (22mm Q235 steel ),Diaphragm in door lid (2.5mm Q235 steel )\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy saving\u003c\/strong\u003e\u003cbr\u003eDynamic compressor control (DCC) technology for optimized cooling performance. When the door lid is opened, the compressor is closed or the sleep time can be set to save energy. Rotor with windshield, little friction and generates little heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuper-large Capacity\u003c\/strong\u003e\u003cbr\u003eIt can process sample with the capacity of 8x2200ml,6x2400ml, separating max 17.6L sample in one cycle, which greatly improves the production efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in safety\u003c\/strong\u003e\u003cbr\u003eFeaturing multiple protection, Such as automatic rotor identification, imbalance protection, over-speed protection, over-temperature protection, motor overheating protection, door lid protection and so on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensible\u003c\/strong\u003e\u003cbr\u003eThe system adopts unified and standard Ethernet communication interface and provides key parameter point table, to facilitate system expansion and bring data into system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable\u003c\/strong\u003e\u003cbr\u003eSave up to 3000 user-defined program. Users can name each program to distinguish it. Each program can be divided into 5 steps ( set speed, time, temperature ), to meet the diversified experimental needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACC\/DEC Rates\u003c\/strong\u003e\u003cbr\u003eFeaturing 10 acceleration and 11 deceleration rates, to prevent the sample from second emulsion or turbid, and achieve best centrifuging result.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain interface function\u003c\/strong\u003e\u003cbr\u003eIn manual mode, the centrifuge parameters can be set quickly, and the G-force and speed can be switched by soft touch the key. For the online monitoring of temperature and speed, the stability of temperature and speed during spinning can be viewed through the curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful System Setting Function\u003c\/strong\u003e\u003cbr\u003eRunning data , error code record and operation record can be stored through the system setting. Chinese \/ English operation language optional. And user authority management and other characteristic functions can be managed as well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifuge Management System( Optional)\u003c\/strong\u003e\u003cbr\u003eIt can monitor 1 to 100 centrifuges through intelligent terminal (computer), monitor the operation status of centrifuges, and save relevant records of centrifuge operation, Establish a safe connection with the centrifuge and remotely control the startup and stopping of the centrifuge\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0812\/6427\/9777\/files\/Technical_parameter.png?v=1772787584\" style=\"width: auto;\"\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder NO\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0204258000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%;\"\u003eMax Speed\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eAngle Rotor\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e9000r\/min\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003eSwing Rotor\u003c\/td\u003e\n\u003ctd style=\"width: 20%;\"\u003e4500r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax RCF\u003c\/td\u003e\n\u003ctd\u003eAngle Rotor\u003c\/td\u003e\n\u003ctd\u003e18610xg\u003c\/td\u003e\n\u003ctd\u003eSwing Rotor\u003c\/td\u003e\n\u003ctd\u003e6756xg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Capacity\u003c\/td\u003e\n\u003ctd\u003eAngle Rotor\u003c\/td\u003e\n\u003ctd\u003e6x1000ml\u003c\/td\u003e\n\u003ctd\u003eSwing Rotor\u003c\/td\u003e\n\u003ctd\u003e8x2200ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Setting Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003etwo mode 1min-99h59min,1s-99min59s optional, default mode 1min-99h59min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming mode\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStart Timing after Spinning, Start Timing after Reach Setting Speed, Continuous Timing, Operation at an appointed Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-20°C-40°C, Step 1°C adjustable, The fast pre-cooling temperature can reach -20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Temperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEnsure sample (liquid) temperature accuracy controlled to ±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±10r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAC220±22V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤70dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotor Identification\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImbalance Protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-cooling function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer Control\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRS485 or RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eImbalance Protection, Rotor-identification, Door Lid Anti Pinch Protection, Motor Overheating Protection, Over-Speed Protection,Over-temperature Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (WxDxH)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e875x996x1000(mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimension(WxDxH)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1080x1310x1340(mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e575kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg style=\"width: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0812\/6427\/9777\/files\/Rotor_parameters.png?v=1772787584\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0812\/6427\/9777\/files\/CL8R-R.png?v=1773197150\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Laboratory Centrifuge","offers":[{"title":"Default Title","offer_id":48067226173665,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0812\/6427\/9777\/files\/CL8R.png?v=1773197120","url":"https:\/\/laboratorycentrifuge.net\/products\/cl8r-super-large-capacity-low-speed-super-large-capacity-low-speed","provider":"Laboratory Centrifuge","version":"1.0","type":"link"}